Article · Wikipedia archive · Last revised Aug 1, 2026

Tracer-gas leak testing

A tracer-gas leak testing method is a nondestructive testing method that detects gas leaks. A variety of methods with different sensitivities exist. Tracer-gas leak testing is used in the petrochemical industry, the automotive industry, the construction industry and in the manufacture of semiconductors, among other uses.

Last revised
Aug 1, 2026
Read time
≈ 2 min
Length
509 w
Citations
3
Source

A tracer-gas leak testing method is a nondestructive testing method that detects gas leaks. A variety of methods with different sensitivities exist. Tracer-gas leak testing is used in the petrochemical industry, the automotive industry, the construction industry1 and in the manufacture of semiconductors, among other uses.

Types

Several tracer-gas leak testing methods exist, including:

Method selection

Typical leakage rates

The nature of the product or the process and the process gases will set the leak rate requirement:

System Allowed leak rate (mbar L/s)
Chemical process equipment 10−1–1
Beverage can 10−5 –10−6
Vacuum pumped system 10−5–10−7
IC-package 10−7–10−8
Airbag cartridge 10−8
Pacemaker 10−9
Closed vacuum system 10−9

Sensitivity of methods

Based on the target leak rate, the table below will help to choose the most suitable method.2

Method Sensitivity (leak rate in mbar l/s)
Ultrasonics 10−1
Bubble test in water 10−2
Pressure decay 10−2
Vacuum decay 10−2
Acoustic emission detectors 10−3
Bubble test in soapy water 10−4
Gas-specific thermal conductivity detector 10−5
Halogen detector 10−5
Photoacoustic spectroscopy 10−6
Hydrogen sniffer 10−6
Residual gas analyser 10−7
Dye penetrant 10−8
Radioactive tracer 10−10
Helium mass spectrometry vacuum testing 10−11

Applications

Typical applications of tracer-gas leak testing include:

Standards

Several standards apply to leak testing and more specifically to tracer-gas leak testing methods, for example:

  • BS EN 1779:1999; leak tightness by indication or measurement of gas leakage,
  • BS EN 13185:2001 Non-destructive testing. Leak testing. Tracer gas method,
  • BS EN 13192:2002 Non-destructive testing. Leak testing. Calibration of reference leaks for gases.
References

References

  1. Batajtis, Damian. "Tracer Gas as a Method for Water Leak Detection" (PDF). Wizard Leak Detection. Archived (PDF) from the original on 12 November 2023. Retrieved 12 November 2023.
  2. "Leak Detection Sensitivity Guide - VIC Leak Detection". VIC Leak Detection. Archived from the original on 2022-01-15. Retrieved 2017-06-15.
  3. Townsend, Mark; correspondent, defence (2007-11-11). "MoD accused over spy plane deaths". The Guardian. ISSN 0261-3077. Retrieved 2017-06-15. {{cite news}}: |last2= has generic name (help)